Suitable For
the Most Aggressive Agitated Slurry Solutions and Corrosive Liquids - Recommended for
Installations without guide rod or conduit - Direct Insertion into volatile tank -
COMPLETE CABLE ISOLATION WITH VINYL TUBING AND RUGGED CLAMPS
Option Available For:
- 3/4" MNPT Rear Threaded Immersion Sensors (6X11, 6X12, 6X32 &
6X42 Series Sensors)
- 1" MNPT Rear Threaded Immersion Sensors (6X31, 6X41 Series Sensors)
- 1" MNPT Read Threaded Twist Lock Sensors w/ guard added to front
end (8X31 Sensor Series)
- 1 1/4" MNPT Read Threaded Immersion Sensors - AB 6100 Fluoride
Sensors and other special orders sensors with 1 1/4" MNPT Rear Threadings
Features & Recommended Applications:
- Complete isolation of back end threaded fitting from liquid process and
good protection of cable from corrosion and chemical attack
- Major Rear threading is identical to that specified on original sensor
specifications prior to application of Waterproofing "B" Option
- Hex Head for wrench flats enable easy installations into fixtures
- Recommended for extremely corrosive installations or installations which
do not utilizes any kind of guide rod or conduit, or extremely slurry/viscous solutions
which can abraid cable assemblies
- Recommended primarily for elongating sensor life where attack of liquid
from back end causes death to sensor prior to chemical or physical attack through front of
probe
- For Applications requiring Waterproofing Assemblies to be suited for solvent extraction
(kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions;
Change Waterproofing Description from Waterproofing "B" to "E"
- For Applications Requiring Waterproofing Assemblies to be constructed of only CPVC (for
strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen
peroxide or ozone solutions... etc.); Change Waterproofing part description from
Waterproofing "B" to "H"
- For Applications requiring Waterproofing Assemblies to be suited for both solvent
extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing
solutions and to be constructed of only CPVC (for strong oxidative or reducing solutions -
i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solution... etc.);
Change Waterproofing Description from Waterproofing "C" to "K"
|



Waterproofing "B" Assembly Line
Drawing of Waterproofing "B" Series
|