Features
·
Guaranteed Longest Lasting
Sensors Available with performance guarantee *
·
Sensors are compatible with most
existing pH/ORP Meters, Transmitters & Analyzers **
·
Application Specific Engineering
results in optimum Lifetime & Performance ***
·
Integrated Temperature
Compensation, Preamplifiers & Solution Ground Elements
·
Solid State Reference System offers superior resistance to Fouling
& Dehydration
·
Applications such as Acid/Fluoride,
Hi-Temp, Saturated Sodium and Sulfide Resistant are available as standard
options
·
Custom Applications are available,
often at no additional charge
·
Most Installation Styles are
Supported Including: Immersion, Twist Lock, Valve Retractable
& Sanitary
·
Available in a wide range of plastics,
from cost effective CPVC to thermally & chemically resilient ULTEM®
and PEEK thermoplastic
·
High Pressure Applications up to
100 psi for Valve Retractable & 150 psi for Inline Installations can be
supported for continuous use
·
Operating Temperatures from -30
to +150 ºC (-22 to +302 ºF) can be supported
for continuous use
|

Case Study No. 15 –
Sodium & Calcium
Ion Analysis for
Water Softener Systems
Calcium (Ca++),
Magnesium (Mg++), Sodium (Na+), Ion Analysis
Before and After Water Softener
to determine Water Quality Feed to Boilers
Industrial grade sodium ion
selective membrane and application engineered solid state conductive polymer
reference can withstand the rigors of industrial process lines
Sodium calibration system has
been optimized to yield reproducible results in a variety of boiler water
systems
The Problem
A
company wanted to automate the water quality testing on their water softener
used to feed their boilers. When the softener ceased to function properly,
the water softener needed to be regenerated. A delay in this service may
cause damage to the boilers, eventually leading to a shutdown to clean and
repair the boilers. The existing manual sampling routine or online sampling
analyzers were slow and expensive, respectively. In addition, the delay
caused by not having an accurate real-time online method to determine the
effectiveness of the water softener could cause hard water to spread
throughout the plant, leading to operational difficulties.
The Solution
ASTI's online ion selective sensors can be used to
measure the effectiveness and state of the water softening system, although
this measurement must be performed indirectly. The customer indicated a
desire to measure the activity of calcium (Ca++) ion at a point after
the water softening system. This measurement is not feasible due to the
degree of excess of sodium present. The permissible ratio of excess of
sodium (interfering) ion to calcium (analyte) ion for our calcium ion
selective sensors is 100 fold (on a molar basis), whereas the lab analysis
revealed an excess of 2600 fold (also computed on a molar basis). This then
indicates that the concentration of sodium is 26 times too high to perform
the calcium measurement after the water softener. ASTI found
an excellent and feasible method to indirectly measure calcium after the
softener and determine the effectiveness of the softening system as a whole.
|
Typical
Concentrations Before Softener
Sodium
- Na+ = ~ 48 ppm
Calcium - Ca++ = ~ 160-250 ppm
|
Typical
Concentrations After Softener
Sodium - Na+ = ~ 300 ppm
Calcium - Ca++ = ~0.200-0.600 ppm
|
The ion exchange system is clearly
replacing calcium ions with sodium ions. If the ion exchange system
fails or deteriorates, the sodium ion activity at the post softener location
is changed from about 300 ppm to about 48 ppm. This is almost a step
change in concentration. Measurement of such a change is an appropriate
use of an inline ion selective sensor. At the post softener position,
all concentrations of interfering ions for the sodium ion selective sensor
are within the permissible range. The sodium ion activity as measured
prior to the water softener can provide a valuable baseline sodium ion (Na+)
level. The magnesium ion (Mg++) contribution to water hardness is
ignored because it will be also be converted to sodium ion, which will be analyzed
at the after softener measurement position. In addition, the concentration
of magnesium is often five to ten (5-10) times less than calcium and usually
occurs at a fixed ratio to calcium.
When
the softener is functioning properly, the sodium ion (Na+) levels
as measured after the softener will be quite high (~300 ppm), corresponding
to a lack of calcium ion (Ca++) in the softened water (see
abbreviated water analysis above). When the softener fails to work properly,
the sodium ion levels at the post softener measurement point will return to
the low levels as measured at the before softener measurement point (~30-50 ppm).
This provides a very simple method to use the ion selective system as an
alarm and indicator as to the state of the water softening system. In
addition, the ion selective analyzer can automatically switch the water (via
a relay) to a functioning secondary water softening system to avoid any
downtime. A Rosemount 54e industrial sodium ion selective analyzer was
employed to conveniently calibrate and operate in familiar ppm units. This
ion selective analyzer had the necessary 4-20 mA outputs (scaled in ppm) and
relays (also set in ppm) to enable the automation of this implicit water
hardness (Ca++ & Mg++) determination for water
quality analysis of the water softening system.
The Industrial Sodium Ion Selective
Sensor Used:
Model: AB 8430-100-10 Industrial Sodium Ion Selective
Sensor
Description: 1” MNPT Twist Lock Quick Disconnect ULTEM Bodied Industrial
Sodium Ion Selective Sensor with integrated 100 Ohm Platinum Temperature
Element; 10 feet cable to connect directly to Rosemount 54e Ion Selective
(ISE) Analyzer and Transmitter
Choosing the Correct pH/ORP/ISE Sensor
1.
Choose a sensor body type that
suits the physical parameters of the
installation (refer to the Configurations
Portion of pH/ORP and Ion Selective webpages).
2. Choose
a sensor that suits the process application, temperature,
chemistry, and physical
parameters of the installation (refer to Sensor Selection Guides
and call factory or local sales agent for support)
3. Choose a sensor housing material that is compatible
with the process chemistry, temperature & pressure (refer
to Chemical Resistance Charts as posted under the Technical
Documents portion of the website).
4.
Select suitable temperature compensation element, solution
ground & integrated preamplifier based upon mating pH/ORP/ISE Instrument (refer to Electrochemical Instrumentation Page & ask for factory support).
5.
Specify the required
cable length based
upon installation
location (refer
to Part Numbering Guide).
*
Subject to application qualification and review by an approved ASTI sales
agent and/or factory. Performance guarantee is posted on the ASTI online
application questionnaire page.
**
See list of supported pH/ORP/ISE Instruments webpages as posted on the ASTI website.
***
Completion of Application Questionnaire form is required. Other restrictions
may apply.
|