Waterproofings Options for Aggressive & Corrosive Liquid Process Applications

Waterproofings are an optional feature which allows ASTI to excel in hazardous and/or corrosive environments.  The excellent sealing offer by our three major series of waterproofing/sealing assemblies ensures that the our sensors will not be prematurely killed by chemical or mechanical attack from the rear end of a submersed sensor.

 

Waterproofing Style "A" Series

Suitable For Most Ordinary Completely Submersible Installations

Option Available For:

  • 3/4" MNPT Rear Threaded Immersion Sensors (6X11, 6X12, 6X32 & 6X42 Series Sensors)
  • 1" MNPT Rear Threaded Immersion Sensors (6X31, 6X41 Series Sensors)
  • 1" MNPT Read Threaded Twist Lock Sensors w/ guard added to front end (8X31 Sensor Series)
  • 1 1/4" MNPT Read Threaded Immersion Sensors - AB 6100 Fluoride Sensors and other special orders sensors with 1 1/4" MNPT Rear Threadings

Features & Recommended Applications: 

  • Complete isolation of back end threaded fitting from liquid process and good protection of cable from corrosion and chemical attack
  • Rear threading is identical to that specified on original sensor specifications prior to application of Waterproofing "A" Option
  • Hex Head for wrench flats enable easy installations into fixtures
  • Not recommended for extremely corrosive installations or installations which do not utilizes any kind of guide rod or conduit
  • Recommended primarily for elongating sensor life where attack of liquid from back end causes death to sensor prior to chemical or physical attack through front of probe
  • For Applications requiring Waterproofing Assemblies to be suited for solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions; Change Waterproofing Description from Waterproofing "A" to "D"
  • For Applications Requiring Waterproofing Assemblies to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solutions... etc.); Change Waterproofing part description from Waterproofing "A" to "G"
  • For Applications requiring Waterproofing Assemblies to be suited for both solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions and to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solution... etc.); Change Waterproofing Description from Waterproofing "A" to "J"
WPA_01a.jpg (26672 bytes)
WPA_03_Useda.jpg (12607 bytes)
Waterproofings after "use" in Process

Download PDF Line Drawing of Waterproofing "A" Series

Waterproofing Style "B" Series

Suitable For the Most Aggressive Agitated Slurry Solutions and Corrosive Liquids - Recommended for Installations without guide rod or conduit - Direct Insertion into volatile tank - COMPLETE CABLE ISOLATION WITH VINYL TUBING AND RUGGED CLAMPS

Option Available For: 

  • 3/4" MNPT Rear Threaded Immersion Sensors (6X11, 6X12, 6X32 & 6X42 Series Sensors)
  • 1" MNPT Rear Threaded Immersion Sensors (6X31, 6X41 Series Sensors)
  • 1" MNPT Read Threaded Twist Lock Sensors w/ guard added to front end (8X31 Sensor Series)
  • 1 1/4" MNPT Read Threaded Immersion Sensors - AB 6100 Fluoride Sensors and other special orders sensors with 1 1/4" MNPT Rear Threadings

Features & Recommended Applications: 

  • Complete isolation of back end threaded fitting from liquid process and good protection of cable from corrosion and chemical attack
  • Major Rear threading is identical to that specified on original sensor specifications prior to application of Waterproofing "B" Option
  • Hex Head for wrench flats enable easy installations into fixtures
  • Recommended for extremely corrosive installations or installations which do not utilizes any kind of guide rod or conduit, or extremely slurry/viscous solutions which can abraid cable assemblies
  • Recommended primarily for elongating sensor life where attack of liquid from back end causes death to sensor prior to chemical or physical attack through front of probe
  • For Applications requiring Waterproofing Assemblies to be suited for solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions; Change Waterproofing Description from Waterproofing "B" to "E"
  • For Applications Requiring Waterproofing Assemblies to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solutions... etc.); Change Waterproofing part description from Waterproofing "B" to "H"
  • For Applications requiring Waterproofing Assemblies to be suited for both solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions and to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solution... etc.); Change Waterproofing Description from Waterproofing "C" to "K"
WPB_01a.jpg (10619 bytes)
WPB_02a.jpg (6118 bytes)
WPB_04_Detaila.jpg (18828 bytes)
Detail of Waterproofing "B" Assembly including vinyl tubing and clamps

Download PDF Line Drawing of Waterproofing "B" Series

Waterproofing Style "C" Series

Suitable For the Most Aggressive Agitated Slurry Solutions and Corrosive Liquids - Recommended for Installations without guide rod or conduit - Direct Insertion into volatile tank -

Recommended for similar Installations as Waterproofing Style "B" - Lacks the complete Cable Isolation offered by "B" Style

Option Available For: 

  • 3/4" MNPT Rear Threaded Immersion Sensors (6X11, 6X12, 6X32 & 6X42 Series Sensors)
  • 1" MNPT Rear Threaded Immersion Sensors (6X31, 6X41 Series Sensors)
  • 1" MNPT Read Threaded Twist Lock Sensors w/ guard added to front end (8X31 Sensor Series)
  • 1 1/4" MNPT Read Threaded Immersion Sensors - AB 6100 Fluoride Sensors and other special orders sensors with 1 1/4" MNPT Rear Threadings

Features & Recommended Applications: 

  • Complete isolation of back end threaded fitting from liquid process and good protection of cable from corrosion and chemical attack
  • Rear threading is identical to that specified on original sensor specifications prior to application of  Waterproofing "C" Option
  • Hex Head for wrench flats enable easy installations into fixtures
  • Not Recommended for extremely installations which do not utilizes any kind of guide rod or conduit
  • Recommended for extremely corrosive and/or slurry, viscous or high-speed process solutions which can abraid cable assemblies
  • Recommended primarily for elongating sensor life where attack of liquid from back end causes death to sensor prior to chemical or physical attack through front of probe
  • For Applications requiring Waterproofing Assemblies to be suited for solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions; Change Waterproofing Description from Waterproofing "C" to "F"
  • For Applications Requiring Waterproofing Assemblies to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solutions... etc.); Change Waterproofing part description from Waterproofing "C" to "I"
  • For Applications requiring Waterproofing Assemblies to be suited for both solvent extraction (kerosene and other heavy hydrocarbons) or solvents/organic media containing solutions and to be constructed of only CPVC (for strong oxidative or reducing solutions - i.e. chlorine, chlorine dioxide, strong hydrogen peroxide or ozone solution... etc.); Change Waterproofing Description from Waterproofing "C" to "L"
waterproofingC_lowanglea.jpg (27014 bytes)
waterproofingC_midanglea.jpg (37082 bytes)
waterproofingC_detaila.jpg (21982 bytes)
Detail of Waterproofing "C" Assembly including grommett sealing on cable

Download PDF Line Drawing of Waterproofing "C" Series